Material Description and Usage
Provided here is a brief explanation of some of the products we install.
Look through the pages below and find one suitable for your application.
If you do not find the product listed here please call or E-mail and speak to the owner.

|
|  |
 |
 |

- Superior Radiant Insulation - Type 2 Silver Foil Capsheet
|
SUPERIOR FACTORY TYPE 2 ALUMINUM REFLECTIVE INSULATION
THERMAL PERFORMANCE DATA 2 X 6:
|
Resistance Factor for Reflective Insulation Systems only |
DOWN |
R-12 |
|
UP |
R-4.5 |
|
Installed Resistance Factor Air to Air
|
DOWN |
R-13 |
|
UP |
R-5.9 |
Values shown are from ASTM C-236 guarded hot box test performed by a NVLAP accredited and State of California approved laboratory, and test data from ASHRAE fundamentals handbook. All R values for heat flow include 1.32 R for still air, and all R values for heat flow down includes 4.55 R still air.
MATERIAL Superior Factory Type 2 aluminum reflective insulation is composed of 100LB. Kraft paper faced on both sides with aluminum foil. During the lamination process a heavy application of flame retardant adhesive is applied to both sides of the Kraft paper to make it flame resistant and achieve a low flame spread.
Superior Factory Type 2 is available with white on exposed facing. Superior Factory Type 2 aluminum reflective insulation also has the following advantages:
- Low in cost
- Covers all roof rafters to give a simi-finished ceiling that never needs paint.
- Increases light reflectivity, thereby decreasing the amount of light needed.
- Is especially beneficial in an exposed rafter application in industrial and commercial
buildings. When installed exposed below unfaced mineral fiber blanket insulation or multiple layer aluminum insulation , additional insulation value is achieved (see ASHREA guide for reflective insulation values). When tested for vapor trans- mission as per ASTM E 96 procedure B, the following results were achieved: WVT=).22 gm/M2.24 hr. performance = 0.22 perms, which meets CEC and UBC regulations.
RECOMMENDED METHOD OF SPECIFYING Superior Factory Type2 aluminum insulation shall be installed only by qualified mechanics.
INSTALLATION Face staple Superior Factory Type 2 to bottom of rafters, staples to be approximately 6" o.c. Material shall be installed as a single sheet the full length of the rafters and turned down approximately 1½" at ends where possible, and stapled to both the perlin or main rafter support. Ends shall be neatly trimmed.
WARNING Do not install insulation under a roof that is not dry. Insulating a wet roof may cause condensation and damage to insulation and roof deck.
NOTE When tested by the ASTM E 84 Flame Spread Test the following results were achieved: Flame Spread 5 Smoke Developed 15
Superior Aluminum Insulation products are state certified and meet the State of California Quality Standards.
|

|
Steel Truss Panelized Roof System |
|

|
Bow String System Truss Roof |
|

|
Wood Joist, Steel 1 Beam Roof System |
|

|
Panelized Roof System (Occupied Application) | |
|  |
 |
 |
- Superior Radiant Insulation - Type 2 Black Foil Capsheet
|
SUPERIOR FACTORY TYPE 2 DECORATIVE BLACK INSULATION
Superior Factory Type 2 is available with white or custom colors on exposed facing. Superior Factory Type 2 black insulation also has the following advantages:
- Low in cost
- Covers all roof rafters to give a simi-finished ceiling that never needs paint.
- Is especially beneficial in an exposed rafter application in industrial and commercial
buildings. When installed exposed, below unfaced mineral fiber blanket insulation or multiple layer aluminum insulation , additional insulation value is achieved.
RECOMMENDED METHOD OF SPECIFYING Superior Factory Type2 insulation shall be installed only by qualified mechanics.
INSTALLATION Face staple Superior Factory Type 2 to bottom of rafters, staples to be approximately 6" o.c. Material shall be installed as a single sheet the full length of the rafters and turned down approximately 1½" at ends where possible, and stapled to both the perlin or main rafter support. Ends shall be neatly trimmed.
WARNING Do not install insulation under a roof that is not dry. Insulating a wet roof may cause condensation and damage to insulation and roof deck.
NOTE When tested by the ASTM E 84 Flame Spread Test the following results were achieved: Flame Spread 5 Smoke Developed 15
Superior Aluminum Insulation products are state certified and meet the State of California Quality Standards. |
|  |
 |
 |
- Superior Radiant Insulation - Type 2 White Foil Capsheet
|
SUPERIOR FACTORY TYPE 2 WHITE REFLECTIVE INSULATION
When a clean, bright finish is needed: Increases light reflectivity 15% over aluminum |

COMPLETED INSTALLATION PHOTOS
Image 01 Image 02 Image 03 |
Superior Factory Type 2 is available with white and custom colors on exposed facing. Superior Factory Type 2 white insulation also has the following advantages:
- Low in cost
- Covers all roof rafters to give a simi-finished ceiling that never needs paint.
- Increases light reflectivity 15% over aluminum, thereby decreasing the amount of light needed.
- Is especially beneficial in an exposed rafter application in industrial and commercial buildings. When installed exposed below unfaced mineral fiber blanket insulation or multiple layer aluminum insulation , additional insulation value is achieved.
RECOMMENDED METHOD OF SPECIFYING Superior Factory Type2 aluminum insulation shall be installed only by qualified mechanics.
INSTALLATION Face staple Superior Factory Type 2 to bottom of rafters, staples to be approximately 6" o.c. Material shall be installed as a single sheet the full length of the rafters and turned down approximately 1½" at ends where possible, and stapled to both the perlin or main rafter support. Ends shall be neatly trimmed.
WARNING Do not install insulation under a roof that is not dry. Insulating a wet roof may cause condensation and damage to insulation and roof deck.
NOTE When tested by the ASTM E 84 Flame Spread Test the following results were achieved: Flame Spread 5 Smoke Developed 15
Superior Aluminum Insulation products are state certified and meet the State of California Quality Standards. |
|  |
 |
 |
- Superior Radiant Insulation - Type 2 Custom Color Foil Capsheet
|
SUPERIOR FACTORY TYPE 2 CUSTOM COLORS
Similar R-values as our other capsheet products, only in designer colors to match your decor.
Call for details
Photos of installed product
|

  |
|  |
 |
 |
- Superior Radiant Insulation - Type 4 (3 Layer) Multi Layer Aluminum Insulation
|
SUPERIOR TYPE 4 FLAME RETARDANT ALUMINUM REFLECTIVE INSULATION
THERMAL PERFORMANCE DATA 2"x 6": |
 |
|
|
MATERIAL |
R-VALUE DOWN UP |
|
SUPERIOR TYPE 4 |
17.3 |
8.4 |
|
SUPERIOR TYPE 4 W/CAP SHEET |
21.5 |
10.8 |
Values shown are from ASTM C-236 guarded hot box test performed by a NVLAP accredited and State of California approved laboratory, and test data from ASHRAE fundamentals handbook. All R values for heat flow include 1.32 R for still air, and all R values for heat flow down includes 4.55 R still air.
MATERIAL Superior type 4 flame retardant aluminum insulation is a three layer product, composed or two sheets of flame resistant Kraft paper, each faced on one side with aluminum foil, and one of aluminum foil without paper backing.
A higher insulation value and a more pleasing appearance will be achieved by adding Superior Factory Type 2 flame retardant cap sheet face stapled to the bottom of the rafters.
INSTALLATION Grasp blanket by flange with printed side down, position blanket flush against perlin/plate at end of bay, leave gap ¾" to 1" between bottom of flange and face of rafter/truss (when installed between 2"x 4" roof rafters install ½ from face of rafter), begin stapling material approx. 6" o.c. for full length of blanket. Hand held stapler is suggested with a minimum of 3/8" staple. Grasp free flange and pull it taut towards the rafter/truss on right. Line bottom of flange up even with bottom of facing of rafter/truss. Be sure material is pulled over evenly to prevent cross buckles and wrinkles. Finish by stapling full length approx. 6" o.c.
WARNING Do not insulate under a wet deck. Insulating under a wet roof may cause condensation and damage the insulation.
NOTE All Superior Aluminum Insulation products incorporate the use or a special flame resistant paper manufactured to meet the National Bureau of Standards Voluntary Standard PS 46-71 for flame resistant paper. We use a water base non-flammable adhesive to bond the aluminum to the flame resistant paper. When tested by the ASTM E-84 flame spread test, all Superior products have achieved a flame spread of 25 or less. Superior Aluminum Insulation products meet the State of California Quality Standards. |
|  |
 |
 |
- Superior Radiant Insulation - Type 5 (4 Layer) Multi Layer Aluminum Insulation
|
SUPERIOR FACTORY TYPE 5 ALUMINUM REFLECTIVE INSULATION
THERMAL PERFORMANCE DATA 2"x 6": |
 |
|
|
MATERIAL |
R-VALUE
DOWN UP |
|
SUPERIOR TYPE 5 |
20.3 |
10.2 |
|
TYPE 5 W/CAP SHEET |
24.2 |
12.4 |
Values shown are from ASTM C-236 guarded hot box test performed by a NVLAP accredited and State of California approved laboratory, and test data from ASHRAE fundamentals handbook. All R values for heat flow include 1.32 R for still air, and all R values for heat flow down includes 4.55 R still air.
MATERIAL Superior Type 5 flame retardant aluminum insulation is a four layer product, composed of three sheets of flame resistant Kraft paper, each faced on one side with aluminum foil, and one sheet of aluminum foil without paper backing.
A higher insulation value and a more pleasing appearance will be achieved by adding Superior Type 2 flame retardant cap sheet face stapled to the bottom of the rafters.
INSTALLATION Grasp blanket by flange with printed side down, position blanket flush against perlin/plate at end of bay, leave gap ¾" to 1" between bottom of flange and face of rafter/truss (when installed between 2"x 4" roof rafters install ½" from face of rafter), begin stapling material approx. 6"o.c. for full length of blanket. Hand held stapler is suggested with a minimum of 3/8" staple.
Grasp free flange and pull it taut towards the rafter/truss on right. Line bottom of flange up even with bottom of facing of rafter/truss. Be sure material is pulled over evenly to prevent cross buckles and wrinkles. Finish by stapling full length approx. 6" o.c.
WARNING Do not insulate under a wet roof deck. Insulating a wet roof may cause condensation and damage to insulation.
NOTE All Superior Aluminum Insulation products incorporate the use of a special flame resistant paper manufactured to meet the National Bureau of Standards Voluntary Product Standard PS 46-71 for flame resistant paper. We use a water base non-flammable adhesive to bond the aluminum to the flame resistant paper.
When tested by the ASTM-84 flame spread test, all Superior products have achieved a flame spread of 25 or less.
Superior Aluminum Insulation products meet the State of California Quality Standards. |
|  |
 |
 |
- Superior Radiant Insulation - Type 6 (5 Layer) Multi Layer Aluminum Insulation
|
SUPERIOR TYPE 6 FLAME RETARDANT
THERMAL PERFORMANCE DATA 2X6: |
 |
|
|
MATERIAL |
R-VALUE UP |
R-VALUE DOWN |
MEAN R-VALUE |
|
SUPERIOR TYPE 6 |
21.5 |
11.3 |
16 |
|
TYPE 6 W/CAP SHEET |
24.9 |
13.3 |
19 |
Values shown are from ASTM C-236 guarded hot box test performed by a NVLAP accredited and State of California approved laboratory, and test data from ASHRAE fundamentals handbook. All R values for heat flow include 1.32 R for still air, and all R values for heat flow down includes 4.55 R still air.
MATERIAL Superior type 6 flame retardant aluminum insulation is a five layer product, composed of four sheets of flame resistant Kraft paper, each faced on one side with aluminum foil and one sheet of aluminum foil without paper backing.
A higher insulation value and a more pleasing appearance will be achieved by adding Superior Factory Type 2 flame retardant cap sheet face stapled to the bottom of the rafters.
INSTALLATION Grasp blanket by flange with printed side down, position blanket flush against perlin/plate at end of bay, leave gap ¾" to 1" between bottom of flange and face of rafters/truss (when installed between 2"x4" roof rafters install ½" from of rafter), begin stapling material approx. 6" o.c. for full length of blanket. Hand held stapler is suggested with a minimum of 3/8" staple.
Grasp free flange and pull it taut towards the rafter/truss on right. Line bottom of flange up even with bottom of facing of rafter/truss. Be sure material is pulled evenly to prevent cross buckles and wrinkles. Finish by stapling full length approx. 6" o.c.
WARNING Do not insulate under a wet roof deck. Insulating under a wet roof may cause condensation and damage to insulation.
NOTE All Superior Aluminum products incorporate the use of a special flame resistant paper manufactured to meet the National Bureau of Standards Voluntary Products Standard PS 46-71 for flame resistant paper. We use a water base non-flammable adhesive to bond the aluminum to the flame resistant paper.
When tested by the ASTM-84 flame spread test, all Superior products have achieved a flame spread of 25 or less.
Superior Aluminum Insulation products meet the State of California Quality Standards. |
|  |
 |
 |
- Superior Radiant Insulation - Type 2 Scrim
|
Superior FSKF-10 Insulation Facing & Vapor Barrier
MATERIAL Composition-.000285 Aluminum Foil both sides of 30 lb. Kraft (10 lbs. per thousand sq.ft.) with scrim reinforcing, laminated with a flame retardant adhesive.
- Flame Spread 0 per ASTM E-84 Tunnel Test
- Smoke Development- 0 per ASTM E-84 Tunnel Test
- Perm-.02
- Emisivity-.02
- Insulating Value= R-12 Down R-4.5 up when installed as an individual application on the underside of a roof
per ASTM C-236
INSTALLATION FOR ROOF DECKS Install as a single unit spanning the entire length of the underside of the rafter, stapling approximately 6" o.c. and turning ends down approximately 1½" on supporting beams when possible.
OTHER USES Superior FSKF-10 may be used anywhere a tough flame resistant vapor barrier is required.
Lighting-Use of Superior FSKF-10 material on the underside of exposed roof structure may increase lighting by up to 30%
Warning Do not install this product under a wet roof deck as doing so may cause damage to both the material and the deck.
NOTE All Superior Aluminum Insulation Products are state certified and meet the State of California Quality Standards. | |
|  |
 |
 |
- Lamtec - WMP-10 Black
|
WMP-10 BLACK Polypropylene / Scrim /Kraft |
|
 Click To Enlarge
|
|
Installed Products Image:
Small Restaurant
|
|
MEETS ASTM C-1136, TYPE II,IV
|
FACING COMPOSITION |
DESCRIPTION |
VALUES |
| Coating |
Black |
. |
| Film |
Metallized White Polypropylene |
.0015 in (+/- 10%) |
| Adhesive |
Flame Resistant |
. |
| Reinforcing |
Tri-directional |
MD: 4 / inch |
| . |
Fiberglass/Polyester |
XD: 4 / inch |
| Kraft |
White |
14.0 lbs./3000 sf (+/- 10%) | |
FIRE TESTING RESULTS FLAME SPREAD SMOKE DEVELOPMENT UL-723/ASTM E-84 Film Exposed 10 10 Kraft Exposed 15 5 | |
|  |
 |
 |
- Lamtec - WMP-10 White
|
WMP-10 WHITE POLYPROPOLENE /SCRIM / KRAFT
 Click To Enlarge
|
|
| FACING COMPOSITION |
DESCRIPTION |
VALUES (ENGLISH) |
VALUES (METRIC) |
| White Film |
Metallized Polypropylene |
0.0015 inch |
38.1 micron |
| Adhesive |
Flame Resistant |
. |
. |
| Reinforcing |
Tri-directional |
5 / inch (MD) |
20 / 100mm (MD) |
| . |
Fiberglass/Polyester |
5 / inch (XD) |
20 / 100mm (XD) |
| Kraft |
White |
14 lbs / 3000 ft |
23 gm / m | |
FIRE TESTING RESULTS FLAME SPREAD SMOKE DEVELOPMENT UL-723/ASTM E-84 Film Exposed 10 10 Kraft Exposed 15 5 | |
|  |
 |
 |
- Lamtec - FSF Moisture Resistant
|
FOIL / SCRIM / FOIL MOISTURE RESISTANT
 Click To Enlarge
|
| FACING COMPOSITION |
DESCRIPTION |
VALUES (ENGLISH) |
VALUES (METRIC) |
|
FOIL |
Aluminum |
0.0003 inch |
7.6 micron |
|
ADHESIVE |
Flame Resistant |
. |
. |
|
REINFORCING |
Bi-directional |
4/inch (MD) |
16/100mm (MD) |
|
. |
Fiberglass |
4/inch (XD) |
16/100mm (XD) |
| FOIL |
Aluminum |
0.0003 inch |
7.6 micron |
FIRE TESTING RESULTS FLAME SPREAD SMOKE DEVELOPMENT UL-723/ASTM E-84 Film Exposed 10 10 Kraft Exposed 15 5 | |
|
 |