MATERIAL Composition-.000285 Aluminum Foil both sides of 30 lb. Kraft (10 lbs. per thousand sq.ft.) with scrim reinforcing, laminated with a flame retardant adhesive.
- Flame Spread 0 per ASTM E-84 Tunnel Test
- Smoke Development- 0 per ASTM E-84 Tunnel Test
- Perm-.02
- Emisivity-.02
- Insulating Value= R-12 Down R-4.5 up when installed as an individual application on the underside of a roof
per ASTM C-236
INSTALLATION FOR ROOF DECKS Install as a single unit spanning the entire length of the underside of the rafter, stapling approximately 6" o.c. and turning ends down approximately 1½" on supporting beams when possible.
OTHER USES Superior FSKF-10 may be used anywhere a tough flame resistant vapor barrier is required.
Lighting-Use of Superior FSKF-10 material on the underside of exposed roof structure may increase lighting by up to 30%
Warning Do not install this product under a wet roof deck as doing so may cause damage to both the material and the deck.
NOTE All Superior Aluminum Insulation Products are state certified and meet the State of California Quality Standards. |